SUN HYDRAULICS
PPDFQON


$90.47 USD
  • SUN HYDRAULICS
  • Material:PPDFQON
  • Model:PPDF-QON
  • Summary:Cartridge

Due to extremely high demand, please call for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPDFQON (PPDFQON) is a pilot-operated pressure reducing/relieving valve designed to reduce a high primary pressure at the inlet port 2 to a constant reduced pressure at port 1, while providing a full-flow relief function from port 1 to tank port 3. The valve features a main stage orifice drilled into the piston, enhancing its durability for demanding applications. It is important to note that the maximum pressure at port 3 should be limited to 3000 psi (210 bar) and is directly additive to the valve setting in a 1:1 ratio. This valve is not fast-acting; for applications requiring superior dynamic response, direct acting valves are recommended. The recommended maximum inlet pressure varies by adjustment range: Ranges D, E, N, and Q handle up to a 2000 psi (140 bar) differential between inlet and reduced pressures; Ranges A, B, and H accommodate up to a 3000 psi (210 bar) differential; Ranges C and W are tested with an inlet pressure of up to 5000 psi (350 bar). The valve exhibits exceptionally flat pressure-flow characteristics, ensuring stability with low hysteresis. Reverse flow from reduced pressure port 1 to inlet port 2 may close the main spool. If reverse free flow is necessary in your circuit, consider adding a separate check valve. For critical pilot flow consumption scenarios, direct acting reducing/relieving valves may be more suitable. All three-port cartridges are interchangeable within their frame size. The Sun floating style construction minimizes the risk of internal parts binding due to excessive installation torque or machining variations. The PPDFQON has a capacity of 10 gpm (40 L/min), operates at pressures up to 5000 psi (350 bar), and features easy adjustment capabilities with specified control options available for tailored settings.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.