SUN HYDRAULICS
CBCARHN


$68.44 USD
  • SUN HYDRAULICS
  • Material:CBCARHN
  • Model:CBCA-RHN
  • Summary:Cartridge

Due to extremely high demand, please call for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBCARHN (CBCARHN) is a highly efficient counterbalance valve with pilot assist designed to control overrunning loads in hydraulic systems. This valve features a check valve that permits free flow from port 2 to port 1, while a direct-acting, pilot-assisted relief valve manages the flow from port 1 to port 2. The pilot assist at port 3 effectively reduces the relief valve setting based on the pilot ratio, enhancing control and responsiveness. The CBCARHN is engineered for robust performance with a maximum setting of 4000 psi (280 bar) and a capacity of up to 15 gpm (60 L/min). It is equipped with an adjustment feature that allows for precise control; turning the adjustment clockwise decreases the setting and releases the load. The design includes Sun’s floating style construction which minimizes internal parts binding, ensuring reliable operation even under varying installation conditions or cavity/cartridge machining discrepancies. This model also accommodates various configurations with EPDM seals suited for phosphate ester fluids, emphasizing its versatility in different hydraulic environments. Notably, this valve does not have positive seals on the pilot section and may pass fluid between ports under certain conditions, which should be considered in master-slave circuits or when leak testing valve/cylinder assemblies. Overall, the Sun Hydraulics CBCARHN counterbalance valve provides effective load control and stability in hydraulic systems, making it an essential component for applications requiring precise motion control and load handling.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • This valve does not have positive seals on the pilot section and will pass up to 3 in³/min.@1000 psi (45 ml/min.@70 bar ) between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 15 gpm60 L/min.
Pilot Ratio 3:13:1
Maximum Recommended Load Pressure at Maximum Setting 3075 psi215 bar
Maximum Setting 4000 psi280 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic StandardStandard
Reseat >85% of setting>85% of setting
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .40 lb0,20 kg
Seal kit - Cartridge Viton: 990-011-006

Show FAQ